PM3 Commands Reference (Iceman Firmware):

Main Help


Current command:
lf em 410x brute --help


bruteforcing by emulating EM 410x tag

usage:
    lf em 410x brute [-h] [--clk <dec>] [--delay <dec>] -f <hex> [--gap <dec>]

options:
    -h, --help                     This help
    --clk <dec>                    <32|64> clock (default 64)
    --delay <dec>                  pause delay in milliseconds between UIDs simulation (default 1000ms)
    -f, --file <hex>               file with EM Tag IDs, one id per line
    --gap <dec>                    gap (0's) between ID repeats (default 20)

examples/notes:
    lf em 410x brute -f ids.txt
    lf em 410x brute -f ids.txt --clk 32
    lf em 410x brute -f ids.txt --delay 3000
    lf em 410x brute -f ids.txt --delay 3000 --clk 32